Alltrax controller fault codes. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV....

Re: Alltrax SR48500 low throttle input underrange. Th

Caterpillar engine fault codes can be read with diagnostic software. This software is available at all reputable mechanics, or it can be purchased for use at home or on the road. T...Sep 26, 2021 · The single LED light on the controller is flashing 5,5 which according to Curtis means MAIN DROPOUT or Main Contactor Open or possible defective contactor. I replaced the solenoid with a heavier duty White Rodgers 48v solenoid hoping that was the problem. It is actually worse and will barely move.Unexchanged or unsurrendered stocks are those shares that should have changed hands but have not. When a share goes unexchanged, it is typically the fault of the company issuing th...Pack is at 48-49v -I have not charged it since returned home, plan on charging it tonight. Low voltage cut off is set around 20v so this is not the problem. I plugged the computer into the alltrax controller (sr48500) and it is communicating fine, responding to the throttle input, and everything else seems normal- NO ERROR CODES.Max throttle and verify LED turns to an amber color. Check throttle if light doesn’t change. Monitor voltage on Controller B- and M-. At 0% throttle, the voltage should be the same as pack voltage. At 100% throttle voltage should be near zero. If voltage starts or stops at » 1⁄2 pack voltage, replace F/R switch.Re: Alltrax SR48500 low throttle input underrange. Quote: Originally Posted by JohnnieB. Across J4 and J5 with the white and black wires attached ought to be 10V when solenoid clicks and 6V with pedal on floor, so both of the readings you got were way out of range on the low voltage side. Disconnect the white and black wires from J4 and J5 and ...Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: Alltrax XCT500 EZGO ITS throttle codesI watched the status light on the controller while depressing the throttle, and after I get the first green light indicating a 0-5K throttle, I get 2 green lights and 6 red lights; the controller instructions says that indicates "Low Throttle under range".Jul 18, 2021 · Repaired Controller + 1st eGator = 3,1 fault code. Running Controller + 1st eGator (again) = 3,1 fault code. Looking into the technical manual for the 1268 controller, they report the 3,1 fault code as: Fault {3,1} MAIN DRIVER OFF - Main contactor driver held high. Possible solutions: 1. Main contactor coil shorted. 2.I would call Alltrax tech support before getting a new controller. Not sure how you can get 70+ volts out of a system that only has 50.7v. Ours will be at 51.4v and drop to 49v or so when starting.Controllers Suggested types: SW180 W&R 586 (Shown) Heavy Duty 200 aMp (800A Inrush) Use with 300A to 500A Controllers Suggested types: MZJ200 (Shown) Heavy Duty 400 aMp (1000A Inrush) Use with 500A Controllers Suggested types: SW200 MZJ400 (Shown) HeaVy DuTyIn the popular online game Blox Fruit, players can embark on exciting adventures as they navigate different islands, battle formidable foes, and unlock powerful abilities. Blox Fru...Extreme DC! Extreme Electric Golf Carts!One of the new features of the Alltrax SPM and XCT/SR controllers is ease of upgrading the controller's firmware. When the controller is connected to Toolkit program, the program will check the version of controller firmware. If there is a new update available, the user will be prompted to upgrade the controller with a screen similar to this:Alltrax SR48400 Pdf User Manuals. View online or download Alltrax SR48400 Operator's Manual ... Brands; Alltrax Manuals; Controller; SR48400; Alltrax SR48400 Manuals. Manuals and User Guides for Alltrax SR48400. We have 1 Alltrax SR48400 manual available for free PDF download: Operator's Manual ... Blink Codes. 29. Warranty Statement. 31 ...Re: 2012 G29 48V Alltrax Woes. Normally a 3 amp diode. The precharge resistor is built into the Alltrax controller so you do not want one on the solenoid. One Green 6 Red is "Precharge Failure" which suggests that the controller is not getting battery voltage from the hot side of the solenoid. 11-16-2023, 03:26 PM.In today’s fast-paced world, staying connected is a necessity. Whether it’s for work, school, or keeping in touch with loved ones, having a reliable and affordable wireless plan is...Product Code: CO-XCT-48500-YDRE. Alltrax Controller Options. Qty: Description Manuals & Diagram This is Alltrax's newest line of regen (shunt wound) separately excited motor controllers. ... CO-SR-48500 : Controller Alltrax SR48500 Series/PM 48 volt 500 amp Peak CO-XCT-48500-PDS : Alltrax XCT-48500 Controller 24-48V 500A EZGO PDS Price: $708.00 ...SR-48300 Motor Controller (SR48300) Brand: Alltrax. 3. $56100. DC Motor Controller For Series & Permanent Magent Motors. 300 Amps, 350 Amps (Peak Amp Mode), 12-48 Voltage Range. Flexible USB programming, Auto-throttle calibration for smooth operation. › See more product details.This fault will automatically clear and the charger will restart charging when this problem is removed. Check the battery and connections to the battery. Check the nominal battery voltage. The first two digits of the four digit model name indicate the battery voltage the charger supports.Electronic phase protector is used to protect compressor motors or other three phase motors from voltage faults. Expert Advice On Improving Your Home Videos Latest View All Guides ...Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV. Electric EZ GO Marathon, Medalist, TXT and RXV.ALLTRAX was so good. 3 different guys, ( one called me back after lunch) ran me through all possible problems. ALLTRAX is so amazing. I highly recommend. I could not imagine my 2018 bulletproof ALLTRAX controller was the problem, it was not.from Alltrax and it is not necessary to re-program unless the customer has specific needs. If the controller does need to be programmed it can be done via a USB A to B cable and the Alltrax Toolkit program. Visit our website for more information on programming the controller including the Alltrax Toolkit Manual (DOC113-002) and instructional ...Controllers Suggested types: SW180 W&R 586 (Shown) Heavy Duty 200 aMp (800A Inrush) Use with 300A to 500A Controllers Suggested types: MZJ200 (Shown) Heavy Duty 400 aMp (1000A Inrush) Use with 500A Controllers Suggested types: SW200 MZJ400 (Shown) HeaVy DuTyUnexchanged or unsurrendered stocks are those shares that should have changed hands but have not. When a share goes unexchanged, it is typically the fault of the company issuing th...BLINK CODES The throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, the controller resumes normal operation, except for the Short Circuit alarm that needs a power off cycle to clear the alarm.This kit includes 2 500 amp Alltrax controllers, 1 Bluetooth module for wirelessly connecting to your controllers, 1 wire harness adaptor to connect your existing BBB wire harness to our controller system, and a mounting bracket to mount to you BBB cart. procedure and replacement equipment performed. May 2010.Product Description. Alltrax SR-48500 Motor Controller. - Fan, Fuse & Mounting Hardware Included. - For Series and Permanent Magnet Motors. Features. Color coded terminals. 12-48 Volts. 500 Amps Peak. 575 (Peak Amp Mode)Apr 20, 2019 · Or the B- cable from the batteries to the controllers. 4 Flash. Open circuit fault. This is almost always caused by a loose connection. The first thing to do is connect the PcPak to the controller. This will give you a better explanation of the fault code. A 4 flash is almost always caused by a loose connection. If you have a 4 flash check the ...Another update to the consolidated EV48-400 AC Motor Controller Error/Alarm Codes. These codes apply to Evolution's EV48-400 and EV48-400-A Motor Controllers. They are NOT applicable for the EV48-400-C controller or Curtis controllers (there's a separate 400-C fault list in the files section)Re: alltrax controller 48500 issues. I had exact same issue on my clubcar i2 excell - turns out the throttle was set for a ezgo - when i switch it to clubcar MCOR it worked perfectly. Switching the throttle type was locked by default in my configuration so I had to unlock it in the advanced settings window first.New ALLTRAX XTC 48500 PDS controller Error code Electric EZGOI have a older g19 with a dcx400 controller and the cart won't move. The solenoid clicks when going from tow to run and the controller will blink green and then 2 red. From what I have read it's a under temp code. I also read that if the frame is showing voltage it could cause the code.ALLTRAX XCT500 36v Battery Under Voltage error code Electric EZGOPage 1 Solid Green: Controller ready to run Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Red: Controller in programming mode no cost to the customer, except for shipping costs of sending the defect...; Page 2 E-Z-Go Diagram Motor Controller NPX4834 & NPX4844 for 1994 and Alltrax, Inc. Our NPX Series motor …A Detroit Diesel fault code indicates a specific problem with a Detroit Diesel Series 60 engine. The fault code is displayed when the “check engine” light is activated on a truck p...Alltrax XCT400, Pre-charge Failure. I recently installed an Alltrax XCT400 controller, SW180 solenoid (200 amp), and new cables all around on my late 90s EZGO TXT. Now that everything is installed, I'm getting a green with 6 reds on the status light, which the manual says is a pre-charge failure. If I switch it to tow and then run, the solenoid ...225 SYNCHRONOUS/MIXED CONTROL ERROR: T series (At two-path);This alarm is generated in the following circumstances. (Searched for during synchronous and mixed control command.;1 When there is a mistake in axis number parameter (No. 1023) setting.;2 When there is a mistake in control commanded. ... 5051 M-NET CODE ERROR: Abnormal character ...How to program Alltrax XCT controller. Alltrax XCT 500 settings. RXV Curtis settings. First, you need to test the power. Connect the negative probe to the M terminal and the positive probe to the B+ terminal. Make use of the accelerator to check the controller. Press the accelerator to see the voltage increase.If blank screen is present on remote control then the flow control has shorted out. Unplug flow control. If remote lights up and unit starts operating then replace flow control assembly. 65 Water Flow Servo Faulty (does not stop flow properly) • Check wiring harness to all solenoids for damage and/or loose connections.Product Description. Alltrax EZGO TXT Regen Controller This 300 Amp Alltrax controller is compatible with all 36v or 48v EZGO Regen TXT models 1996 or later. Does not work with Series models. Features: Native OEM connectors eliminate the need for adapter boards or cutting and jumping wires to install a controller. USB programming port.I'm working on an AllTrax DCX 400 controller and I've had a hard time finding the fault code history. In this case, I'm using a personal laptop to "talk" to the controller. ... Car works fine now. 100% sure these controllers don't have the "fault code history" feature. Last edited by amazingjose; 12-31-2020 at 12:30 PM.. Reason: Update …THROTTLE AND BRAKE CODES 29 ALARM CODES 30 CODE DEFINITIONS 32 WARRANTY STATEMENT 33. 4 AC OPERATORS MANUAL ... When installing a new controller, Alltrax recommends the OEM solenoids be replaced with a heavy duty version. ... The fuse must be rated for pack voltage and fault current. 12 AC OPERATORS MANUAL Wiring Controller Min. Wire AWG ...DS IQ new Alltrax fault code. Electric Club Car. Electric Club Car Electric DS, and Precedent golf carsController is not powering up (No LED) Check for voltage on the wire attached to the RED J1 terminal. Verify wiring to the J1 terminals are correct Call Alltrax Tech Support LED blinks 1 green and 1 red Short Circuit/Output Fault Check B+, B- and M- connections on controllerDS IQ new Alltrax fault code. Electric Club Car. Electric Club Car Electric DS, and Precedent golf carsOr the B- cable from the batteries to the controllers. 4 Flash. Open circuit fault. This is almost always caused by a loose connection. The first thing to do is connect the PcPak to the controller. This will give you a better explanation of the fault code. A 4 flash is almost always caused by a loose connection. If you have a 4 flash check the ...300 isn't much. What cart, controller, motor are you posting about?Place the drive axle on jack stands— wheels off the floor. When working on wiring or batteries, always remove rings and watches and use the proper safety equipment, eye protection, and insulated tools. Disconnect batteries before installing or working on the controller. Advertisement.Alltrax SR48400 Series Motor Controller For Taylor-Dunn Golf Carts. $533.00. No reviews yet Write a Review. Throttle Type: * 6-10.5V (Taylor-Dunn) 5K-0 2-Wire. Voltage: * 24 Volt 36 Volt 48 Volt. Optional Cooling Fan: Optional None Cooling Fan & Housing (ASY-XCT-FAN-BLUE) - $38. Optional Solenoid: * None 200 Amp Main Solenoid w/ Diode ...Max throttle and verify LED turns to an amber color. Check throttle if light doesn’t change. Monitor voltage on Controller B- and M-. At 0% throttle, the voltage should be the same as pack voltage. At 100% throttle voltage should be near zero. If voltage starts or stops at » 1⁄2 pack voltage, replace F/R switch.Type: Series Motor Controller Operating Frequency: 18kHz Controller Voltage, KSI & Reverse: SR48XXX 12-48V nom, 62V max SR72XXX 12-72V nom, 90V max Controller Operating Temp:-20°C to 75°C, shutdown @ 85°C Environmental Operating Temp: -20°C to 50°C Standby Current (Power up): <1W nom, <8W Fan on Stand By Power : <20mA4. Contact Alltrax for Troubleshooting. Personal Experience: Faced with a non-responsive controller, reaching out to Alltrax's customer service proved invaluable. Steps: Gather Information: Note down your controller's model, serial number, and a brief description of the issue.Below is the test procedures and results for all Alltrax controllers. OEM Curtis controller. tests attached below. Results should be as follows: DCS and Series carts have a signal …How to program Alltrax XCT controller. Alltrax XCT 500 settings. RXV Curtis settings. First, you need to test the power. Connect the negative probe to the M terminal and the positive probe to the B+ terminal. Make use of the accelerator to check the controller. Press the accelerator to see the voltage increase.Product Features. 30-60 VDC (48V models) (60VDC MAX) Control Voltage range: KSI, Throttle Reverse inputs. Control voltage range; Key Switch (KSI), Throttle and Reverse inputs: 24-48 VDC, 60 VDC Max. Reverse Input: 50mA sink max. Standby Current (Powered Up):Then depending how you have the wires hooked up at the V-glide and at controller it will either be a 0-5k or a 5k-0 throttle. Make sure you have the rear wheels of the cart off the ground for testing. Set the throttle type to one of those in the toolkit and see how it responds. ... Alltrax SR48400 code Throttle range errorThe controllers RS-232 serial port is referenced to the B- battery connection. Beware of any possi-ble ground loop faults between your com-puter and the controller which could damage both the AXE Controller and PC, or cause per-sonal injury. Hardware : Use a STRAIGHT-THROUGH DB-9 pin / RS-232 serial interface cable to connect the control-Product Description. Alltrax XCT-48400 YDRE Motor Controller For Yamaha Drive Golf Carts. This is Alltrax's newest line of regen (shunt wound) separately excited motor controllers. It offers many advantages over their older DCX line. Note: The YDREX is using the same controller as the YDRE in the DC motor carts.None of the XCT used a precharge resistor. The early models (2015-2016.5) did use the spark arresting diode. But sometime mid to late 2016 The manufacture got smart and integrated the diode into the controller because so many people left it off or worse installed it backwards.Re: Alltrax Blink Codes - maybe the controller's ok? Quote: Originally Posted by Gigaquad. My controller on my new-to-me cart is supposed to be bad, but I discovered it has blink codes. Cart: Ezgo TXT Series model Model: Altrax SR400 Blink: green green, red red red = which seems to mean "High Throttle Over Range" My thinking is that they didn't ...Maytag washers are known for their durability and reliable performance. However, like any other appliance, they can occasionally encounter issues that may display error codes on th...Model: DCX300 / DCX400 / DCX500 / DCX600. Type: Separately Excited (Shunt) DC motor controller. Battery Input Voltage: 24 – 48VDC Nominal, (60VDC max) Under voltage cutback: adjustable, 16-30 VDC. Over …pairs, improper installation, submersion, alterations or use contrary to. any instructions provided by Alltrax in verbal or written form. In the event you should need warranty repair, contact Alltrax at (541) 476-3565 to receive warranty service authorization instructions for. returning the defective product to Alltrax for evaluation.EZ-GO Performance Shunt Motor Controllers. EZ-GO DCS/FAIRPLAY. Select options. XCT48300DCS 36 or 48 Volt 300 Amp $ 747.00 - $ 778.00; Select options. XCT48400DCS 36 or 48 Volt 400 Amp $ 834.00 - $ 865.00; ... Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected] Subscribe to Our Mailing ...Hardware: Use a STRAIGHT-THROUGH DB-9 pin / RS-232 serial interface cable to connect the controller to the PC. Alternatively use the preferred DB-9 pin RS-232 serial port to USB adapter. The DCX controller must be powered before the ControllerPRO program will have any effect. Before programming the DCX, READ THE SAFETY NOTES BELOW.View online or download Alltrax SR48400 Operator's Manual. ... Alltrax Manuals; Controller; SR48400; Alltrax SR48400 Manuals. ... Blink Codes. 29. Warranty Statement. 31.Posts: 73,265. Re: Alltrax SPM 48300 EZ 4 blink green. If the LED goes solid green after 4 green flash it is good to go. (as explained above) Push the go pedal to the floor and the green light should turn orange indicating the controller is seeing a full throttle signal. This would eliminate the possibility of a throttle signal problem.I have taken it completely apart and removed all wiring motor and controller. All parts that moved I replaced. I'm new to golf carts but thought I could do it based on most of the wiring being plug and play. I decided to upgrade the controller to a Alltrax 400amp XT controller, 400 amp heavy duty contactor and a new Admiral A2 10hp motor.XCT-48400 Alltrax Controller – This golf cart controller is for Yamaha 48V Motors - Regen motors only - free programming cable & solenoid brackets included ; This Alltrax controller is an economical way to gain enhanced torque, thermal capabilities, and speed (Alltrax Controller) This Alltrax Controller is usable out of the box (plug and play).However, the controller on the beginning of the video is a plain controller with spade connectors, which is why the solenoid keeps clicking as the "pedal micro-switch" input signal is just a "logic" signal and easily disturbed by low current (water interference). The controller on the second half of the video (HD) has the water tight connectors.Car fault codes can be a significant headache for car owners. When a warning light appears on the dashboard, it’s essential to know what the issue is to prevent further damage or p...You are wasting your money though if you are planning on going to an Alltrax controller (Which does not need a PTV code to give you faster speeds) The $150 is a rip-off IMO since all it does is allow the controller to increase the max speed. 07-30-2016, 10:54 AM. # 3. cgtech vbmenu_register ("postmenu_1300528", true);View and Download Alltrax AC1 operator's manual online. AC1 controller pdf manual download. Also for: Txt48, Pds, Dcs.Trouble Shooting. Error code display:# of RED blinks. indicates any error conditions that might. exist: 1 Red = Throttle Position Sensor Over. Range. Check for open wires. 2 Red …1) "Control voltage range for Key Switch (KSI), Throttle and Reverse inputs: 24-48 VDC Nom, 60 VDC Max " 2) no its not isolated, the control board references ground (from an email from alltrax " At this time, the monitoring system is really a as needed basis because of the potential ground loop issues that can destroy the controller or computer ...Voltage: * 36 Volt 48 Volt. Optional Solenoid: * None 400 Amp Main Solenoid w/ Diode & Resistor - $122. Add to Wish List. SKU: CON-SR48600-EZGo. Availability: In Stock. Product Description. Alltrax SR-48600 Motor Controller.Engine Overspeed. Engine overspeed "is indicated by fault code FC_6 and six blinks on the LED indicator. This feature protects devices connected to the transfer switch by shutting the generator down if the engine happens to run faster than the preset limit. The overspeed fault is detected as follows: if the generator output frequency is 65-70 ...2. If Step 1 doesn't solve the error, the Hall Sensor plug connection (white plug) from your controller to your motor core may have come loose or has silicone interference impeding the connection. In order to fix this, you need to loosen the controller from the motor to unplug and replug the white Hall Sensor plug. You will need to check all ...The single LED light on the controller is flashing 5,5 which according to Curtis means MAIN DROPOUT or Main Contactor Open or possible defective contactor. I replaced the solenoid with a heavier duty White Rodgers 48v solenoid hoping that was the problem. It is actually worse and will barely move.Page 1 Solid Red: Controller in programming mode may be rejected. Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Yellow: Controller throttle is wide no cost to the customer, except for shipping costs of sending the defect open, controller is supplying max output, For Stock PDS &...Posts: 23. Alltrax XCT High Throttle Input Under range. I have a 2007 Club Car DS that I upgraded the controller and motor on back in 2016. Controller is an Alltrax XCT 48 volt 500 amp and the motor is a D&D 502.2. I upgraded the solenoid and cables at the same time. Bought everything from Scotty B. Everything has worked fine until recently.AllTrax 48500 SR Current Limit Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.. One of the new features of the Alltrax SPM and XCT/SRThe throttle code blinks on controller power u I fully charged the new set and went for a ride this am to my dismay, the battery voltage on full charge was dropping and staying between 44-45 volts under load on the flat). I'm still getting 31 mph out of the motor but the volts arent right and the amps are high which is going to put the heat back into the controller. View online or download Alltrax SR48400 What to Do. Check the fan connection. Turn off and unplug your grill. If your hopper has a bottom service panel, remove it by unscrewing the screws securing it in place. Locate your draft induction fan. If having difficulty, find the orange wires and follow them to the fan. If the fan is connected but Er4 still appears, contact Customer Support. Page 1 6 Green = Taylor-Dunn 6-10.5V Mini-Manual Alltrax reserv...

Continue Reading